uv sterilization

THIS SITE IS MOVING, PLEASE ORDER UV SYSTEMS HERE:
http://www.rosystems.com
This
modular line of ultraviolet disinfection systems can be used in a myriad
of applications where flexibility and pricing sensitivity is an deciding
factor. The small SQ-PA through S2Q-PA systems are ideally suited for
point-of-use filtration, RO pre or post disinfection, while the larger
S5Q-PA - S12Q-PA systems can be used on a point-of-entry (whole home)
system disinfection the water for an entire home or cottage. The low
pressure germicidal lamps provide an economical way of treating water
requiring a 99.99% reduction in bacteria and viruses.
This
process is accomplished without adding any potentially harmful chemicals
to your drinking water. Sterilight is the most ecological way of treating
your water.......and all this just for pennies a day!
These simplistic designs allows for easy homeowner maintenance. The UV
lamp can be changed without interrupting the water flow. The quartz
sleeve design allows for maximum UV output and operating efficiency.
Features
- flow rates of 2
L/min (1/2 gpm) in clear fresh water
- flow rates of 4
L/min (1 gpm) in clear fresh water
- flow rates of
7.5 L/min (2 gpm) in clear fresh water
- flow rates of 19
L/min (5 gpm) in clear fresh water
- flow rates of
30L/min (8 gpm) in clear fresh water
-
NEW electronic "ICE" ballasts
featuring open loop current control (patent pending), ballast features
IEC connector, audible alarm & power-on indicator
- hard glass, low
pressure mercury vapour lamps with high isolation pin design
- quick-lock
moulded lamp connector
- compact design
incorporating 304 stainless steel reactor chambers, brilliantly
polished for laboratory or medical applications
- easy servicing -
no need to disconnect water flow to change UV lamp
- open end quartz
sleeves and aluminum gland nuts for optimum operating temperature and
sealing efficiency
- 99.99%
destruction of bacteria, virus, and protozoan cysts (Giardia lamblia &
cryptosporidium) at rated flow
- natures way to
protect your water without the addition of harmful chemicals
- includes
mounting clamp
- seven year
warranty on reactor chamber for unparalleled protection
- product
certified by CSA (C US) and CE
Warranty
The Sterilight
SQ-PA, S1Q-PA, S2Q-PA, S5Q-PA, S8Q-PA and S12Q-PA water disinfection systems carry
a seven year warranty on the stainless steel reactor chamber, a one year
warranty on UV lamps, and a five year pro rated warranty on all other
components
|
SPECIFICATIONS
|
|
|
|
\
|
|
|
F
L
O
W
|
U.S. Public Health
16 mJ/cm2
|
7.5
L/min (2 gpm) max
|
15
L/min (4 gpm) max
|
19
L/min (5 gpm) max
|
35.5
L/min (9.5 gpm) max
|
58
L/min (15.5 gpm) max
|
|
R-Can Standard
30 mJ/cm2
|
4 L/min (1 gpm) max |
7.5 L/min (2 gpm) max |
11 L/min (3 gpm) max |
19 L/min (5 gpm) max |
30 L/min (8 gpm) max |
|
NSF / EPA
40 mJ/cm2
|
2 L/min
(0.5 gpm) max |
5.5
L/min (1.5 gpm) max |
7.5
L/min (2 gpm) max |
13.2
L/min (3.5 gpm) max |
22.7
L/min (6 gpm) max |
|
Length
|
30.5 cm (12")
|
38.1 cm (15")
|
43.2 cm (17")
|
53.3 cm (21")
|
90 cm (35")
|
|
Width
|
5.2 cm (2")
|
6.5 cm (2.5")
|
6.5 cm (2.5")
|
6.5 cm (2.5")
|
6.5 cm (2.5")
|
|
Height
|
5.2 cm (2")
|
6.5 cm (2.5")
|
6.5 cm (2.5")
|
6.5 cm (2.5")
|
6.5 cm (2.5")
|
|
Cell Diameter
|
5.2 cm (2")
|
6.5 cm (2.5")
|
6.5 cm (2.5")
|
6.5 cm (2.5")
|
6.5 cm (2.5")
|
|
Shipping Weight
|
2.3 kg (5 lbs.)
|
2.3 kg (5 lbs.)
|
2.7 kg (6 lbs.)
|
3.2 kg (7 lbs.)
|
4.5 kg (10
lbs.)
|
|
Voltage
|
100-130V./50-60Hz.
or 200-250V./50-60Hz.
|
100- 130V./50-
60Hz.
or 200-250V ./50-60Hz.
*
|
100- 130V./50-
60Hz.
or 200-250V ./50-60Hz.
*
|
100- 130V./50-
60Hz.
or 200-250V ./50-60Hz.
*
|
100- 130V./50-
60Hz.
or 200-250V ./50-60Hz.
|
|
Power
Consumption (watts)
|
12
|
16
|
19
|
26
|
39
|
|
Total Lamp
Watts
|
10
|
14
|
17
|
24
|
37
|
|
Maximum
Operating Pressure
|
8.62 bar (125
psi)
|
8.62 bar (125
psi)
|
8.62 bar (125
psi)
|
8.62 bar (125
psi)
|
8.62 bar (125
psi)
|
|
Ambient
Temperature
|
2-40°C
(36-104°F)
|
2-40°C
(36-104°F)
|
2-40°C
(36-104°F)
|
2-40°C
(36-104°F)
|
2-40°C
(36-104°F)
|
|
Quartz Sleeve
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
|
Inlet/Outlet
Port Size
|
1/4" MNPT
|
1/4" MNPT
|
1/2" MNPT
|
3/4" MNPT
|
3/4" MNPT
|
|
Visual "Power
On"
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
|
Audible Lamp
Failure System
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
|
Reactor Chamber
Material
|
304 Stainless
Steel (316L Optional)
|
304 Stainless
Steel (316L Optional)
|
304 Stainless
Steel (316L Optional)
|
304 Stainless
Steel (316L Optional)
|
304 Stainless
Steel (316L Optional)
|
* 12 volt DC
available on request (as model # S1Q-P/12VDC, S2Q-P/12VDC, S5Q-P/12VDC)
CLICK HERE to
download the Installation & Maintenance Manual for
this product. |